Title Sort descending | Date | Size | Publication Number |
---|---|---|---|
*Not current production* For frames 800-5000A (UL1066) and 800-6000A (UL489). Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: | Size: 130518 | Publication Number: DES-093B |
Shows the ground fault protection characteristics. For frames 800-5000A (UL 1066) and 800-6000A (UL489). Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: | Size: 830384 | Publication Number: DES-124 |
Shows the instantaneous, override (HSIOC), and reduced energy let-through instantaneous (RELT) characteristics. For frames 800-5000A (UL1066) and 800-6000A (UL489) and sensors of rating 400-6000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: | Size: 116300 | Publication Number: DES-094B |
Shows fuse-like characteristics. For frames 800-5000A (UL1066) and 800-6000A (UL489) with sensors of rating 400-6000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: | Size: 111979 | Publication Number: DES-091A |
Shows circuit breaker characteristics. For frames 800-5000A (UL1066) and 800-6000A (UL489) with sensors of rating 400-6000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: | Size: 113510 | Publication Number: DES-090A |
Shows short-time pickup and delay bands. For frames 800-5000A (UL1066) and 800-6000A (UL489) with sensors of rating 400-6000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: | Size: 350848 | Publication Number: DES-092B |
Trip unit for PowerBreak II circuit breakers. For frames 800-4000A (PowerBreak). Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: | Size: 126583 | Publication Number: DES-100A |
Shows the ground fault protection characteristics. For frames 800-5000A (AKR & WavePro) and 800-4000A (PowerBreak & PowerBreak II) and trip unit conversion kits of rating 800-5000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: | Size: 897831 | Publication Number: DES-123 |
Shows the ground fault protection characteristics. For frames 800-5000A (AK, AKR, & WavePro) and 800-4000A (PowerBreak & PowerBreak II). Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: | Size: 136801 | Publication Number: DES-098C |
Shows the long-time fuse like characteristics. For frames 800-5000A (AKR & WavePro) and 800-4000A (PowerBreak & PowerBreak II) and ANSI trip unit conversion kits of rating 800-5000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: | Size: 127354 | Publication Number: DES-096B |
Shows the long-time circuit breaker characteristics. For frames 800-5000A (AKR & WavePro) and 800-4000A (PowerBreak & PowerBreak II) and trip unit conversion kits of rating 800-5000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: | Size: 134077 | Publication Number: DES-095B |
Shows the short-time pickup and delay brands. For frames 800-5000A (AKR & WavePro) and 800-4000A (PowerBreak & PowerBreak II) and trip unit conversion kits of rating 800-5000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: | Size: 131954 | Publication Number: DES-097B |
Time Current Curves (12)