Title | Date | Size | Publication Number |
---|---|---|---|
ZTE Series Standard (Open) Transition - Automatic Transfer Switch (ATS), 600-3000Amp power panels, electrical power schematic drawing. Includes: Legend, Operation, 3-line diagram, customer connections, component details, logic layout, MX350 microprocessor functional block diagram. |
Date: | Size: 3327917 | Publication Number: 91A-3000 |
ZTE Series Open Transition - Automatic Transfer Switch (ATS), 4000Amp power panel, electrical power schematic drawing. Includes: Legend, Operation, 3-line diagram, customer connections, component details, logic layout, MX350 microprocessor functional block diagram. |
Date: | Size: 3291421 | Publication Number: 91A-5000 |
ZTE Series Standard (Open) Transition - Automatic Transfer Switch (ATS), 40-150Amp power panels, electrical power schematic drawing. Includes: Legend, Operation, 3-line diagram, customer connections, component details, logic layout, MX350 microprocessor functional block diagram. |
Date: | Size: 3308802 | Publication Number: 91A-1000 |
ZTE Series Standard (Open) Transition - Automatic Transfer Switch (ATS), 225-400Amp power panels, electrical power schematic drawing. Includes: Legend, Operation, 3-line diagram, customer connections, component details, logic layout, MX350 microprocessor functional block diagram. |
Date: | Size: 2181322 | Publication Number: 91A-2000 |
Data Sheet: Includes - Features, benefits, standards, options, model # breakdown, dimensions, lug size/qtys., ordering info. Zenith ZTE Automatic Transfer Switch (ATS). |
Date: | Size: 1319095 | Publication Number: DEA-452 |
User Configurable optional Output modules. Includes the following Outputs: Common Alarm (Any Alarm Active) - (ALM), Self Diagnostic Alarm -(DIAG), Switch Exercising -(EXC), Control Disconnect Switch In Inhibit Position -(DS), ATS Not In Auto Mode -(NIA), Fail To Transfer To Source 1 Alarm -(FTS1), Fail To Transfer To Source 2 Alarm -(FTS2), Engine Start Signal Active -(ESS), Source 1 Failure -(A1), Source 2 Failure -(A1E), Connected To Source 1 -(A4), Connected To Source 2 -(A3), Connected To Center/Neutral -(A34N) (Delay Type Only), Bypass ATS On Source 1 -(AB4), Bypass ATS On Source 2 -(AB3), Programmable Load Control Relay #1 -(LC1), Programmable Load Control Relay #2 -(LC2), Programmable Load Control Relay #3 -(LC3), Programmable Load Control Relay #4 -(LC4), Programmable Load Control Relay #5 -(LC5), Programmable Load Control Relay #6 -(LC6), Auto Load Shed Active -(ALS) (Signal To Shunt Trip Downstream Load/S, Transfer To Source 2 Alarm -(CTAP), User Configuration Digital Alarms -(CCAD-X) Up To Qty. 10, Low Pf Alarm -(LLPFA), Source 1 High Volts THD % Alarm -(VTHDS1), Source 2 High Volts THD % Alarm -(VTHDS2), Current High THD% Alarm -(ITHD), kW Overload Alarm -(LOKWA), Overcurrent (Phase A) -(51A), Overcurrent (Phase B) -(51B), Overcurrent (Phase C) -(51), Overcurrent (Phase N) -(51N), Source 1 Voltage Imbalance Alarm - (VIAS1), Source 2 Voltage Imbalance Alarm - (VIAS2), Current Imbalance Alarm -(CIA), Auto Transfer Occurred Source 1 To Source 2 -(ATS2), Auto Transfer Occurred Source 2 To Source 1 -(ATS1), Manual Transfer To Source 2 From Source 1 Occurred -(MTS2S1), Manual Transfer To Source 1 From Source 2 Occurred -(MTS1S2), Inhibit Transfer To Source 1 -(Q7), Inhibit Transfer To Source 2 -(Q3), Source 1 Undervoltage -(Uvs1), Source 2 Undervoltage -(UVS2), Source 1 Overvoltage -(OVS1), Source 2 Overvoltage -(Ovs2), Source 1 Underfrequency -(UFS1), Source 2 Underfrequency -(UFS2), Source 1 Overfrequency -(OFS1), Source 2 Overfrequency -(OFS2). |
Date: | Size: 267650 | Publication Number: 91R-2002 |
User Configurable optional Input modules. Includes the following inputs: Bypass time delay on re-transfer to source 1 -(BYPTR), bypass time delay on re-transfer to source 2 -(BYPWR), remote engine start -(RSS), auto load shed reset -(LS1R), auto load shed kW pick up on/off -(LS1KW), auto load shed remote enable/disable -(ALS1), no load test -(TSNL), inhibit transfer to source 1 -(Q7), inhibit transfer to source 2 -(Q3), prime source select switch -(S3R), auto/man re-transfer source 2 to 1 -(S5R), auto/man re-transfer source 1 to 2 and source 2 to 1 -(S12/R), commit/no commit to transfer to source 2 -(S13R), manual transfer to source 2 -(YER), manual transfer to source 1 -(YNR), digital input (up to qty. 10 for user-configurable alarms & Flexlogic) - (CCD1-X) |
Date: | Size: 209668 | Publication Number: 91R-2001 |
Date: | Size: 3031432 | Publication Number: 9AKK107991A2521 | |
Date: | Size: 649180 | Publication Number: 1VLC000060 | |
Date: | Size: 13799274 | Publication Number: 1VLG400011 | |
Date: | Size: 11365072 | Publication Number: 1VLC000052 | |
Zone-Selective Interlocking (ZSI) For GE Circuit Breaker and Power Switch Trip Units Application and Technical Guide |
Date: | Size: 2306806 | Publication Number: DET1001 |
Date: | Size: 2306806 | Publication Number: 1SQC930061M0201 | |
Date: | Size: 716298 | Publication Number: 1SDH002011A1604 | |
Date: | Size: 1059361 | Publication Number: 1SDH002009A1602 | |
Date: | Size: 566537 | Publication Number: 9AKK107991A5838 | |
Date: | Size: 3046526 | Publication Number: 9AKK107991A5839 | |
Date: | Size: 1700202 | Publication Number: 9AKK107991A5835 | |
Date: | Size: 3363373 | Publication Number: 9AKK108466A5113 | |
Installation instruction for ZLBM00-100 |
Date: | Size: 1757911 | Publication Number: 9AKK107680A2425 |
Date: | Size: 1128130 | Publication Number: 9AKK107991A6129 | |
Date: | Size: 31002463 | Publication Number: 9AKK106713A4442 | |
Date: | Size: 491717616 | Publication Number: SCADA810_67223 | |
Zenith ATS Quick turn program flyer 19-04.pdf |
Date: | Size: 207239 | Publication Number: 1SCC303011C0201 |
Date: | Size: 11764322 | Publication Number: 9AKK107492A6463 |
Electrical Schematic (46407)