Rev B. For frames 800-5000A (AKR & WavePro) and ANSI trip conversion kits of rating 800-5000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: 09/29/2008 | Size: 101.35 KB | Publication Number: DES-101 |
Applicable with trip units used to retrofit PowerBreak circuit breakers. For frames 800-4000A (PowerBreak). Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: 01/03/2020 | Size: 126.08 KB | Publication Number: DES-099A |
1-page ground fault time-current curve |
Date: 12/01/1994 | Size: 53.93 KB | Publication Number: GES-9914 |
1-page long-time delay, short-time delay and instantaneous time-current curves. |
Date: 11/01/1994 | Size: 42.2 KB | Publication Number: GES-9913 |
1-page ground fault time-current curve |
Date: 12/01/1998 | Size: 51.92 KB | Publication Number: DES-006 |
1-page long-time delay, short-time delay and instantaneous time-current curves. |
Date: 12/01/1998 | Size: 771.21 KB | Publication Number: DES-007 |
*Not current production* For frames 800-5000A (UL1066) and 800-6000A (UL489). Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: 07/30/2015 | Size: 127.46 KB | Publication Number: DES-093B |
Shows the ground fault protection characteristics. For frames 800-5000A (UL 1066) and 800-6000A (UL489). Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: 07/30/2015 | Size: 810.92 KB | Publication Number: DES-124 |
Shows the instantaneous, override (HSIOC), and reduced energy let-through instantaneous (RELT) characteristics. For frames 800-5000A (UL1066) and 800-6000A (UL489) and sensors of rating 400-6000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: 07/30/2015 | Size: 113.57 KB | Publication Number: DES-094B |
Shows fuse-like characteristics. For frames 800-5000A (UL1066) and 800-6000A (UL489) with sensors of rating 400-6000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: 07/30/2015 | Size: 109.35 KB | Publication Number: DES-091A |
Shows circuit breaker characteristics. For frames 800-5000A (UL1066) and 800-6000A (UL489) with sensors of rating 400-6000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: 07/30/2015 | Size: 110.85 KB | Publication Number: DES-090A |
Shows short-time pickup and delay bands. For frames 800-5000A (UL1066) and 800-6000A (UL489) with sensors of rating 400-6000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: 07/30/2015 | Size: 342.63 KB | Publication Number: DES-092B |
Trip unit for PowerBreak II circuit breakers. For frames 800-4000A (PowerBreak). Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: 01/03/2020 | Size: 123.62 KB | Publication Number: DES-100A |
Shows the ground fault protection characteristics. For frames 800-5000A (AKR & WavePro) and 800-4000A (PowerBreak & PowerBreak II) and trip unit conversion kits of rating 800-5000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: 01/03/2020 | Size: 876.79 KB | Publication Number: DES-123 |
Shows the ground fault protection characteristics. For frames 800-5000A (AK, AKR, & WavePro) and 800-4000A (PowerBreak & PowerBreak II). Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: 01/03/2020 | Size: 133.59 KB | Publication Number: DES-098C |
Shows the long-time fuse like characteristics. For frames 800-5000A (AKR & WavePro) and 800-4000A (PowerBreak & PowerBreak II) and ANSI trip unit conversion kits of rating 800-5000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: 01/02/2020 | Size: 124.37 KB | Publication Number: DES-096B |
Shows the long-time circuit breaker characteristics. For frames 800-5000A (AKR & WavePro) and 800-4000A (PowerBreak & PowerBreak II) and trip unit conversion kits of rating 800-5000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: 01/02/2020 | Size: 130.93 KB | Publication Number: DES-095B |
Shows the short-time pickup and delay brands. For frames 800-5000A (AKR & WavePro) and 800-4000A (PowerBreak & PowerBreak II) and trip unit conversion kits of rating 800-5000A. Curves apply for 60 Hz frequency and ambient temperatures from -20 C to 55 C. |
Date: 01/03/2020 | Size: 128.86 KB | Publication Number: DES-097B |